SCI ERV-24-HC11 Spécifications

Naviguer en ligne ou télécharger Spécifications pour Thermostats SCI ERV-24-HC11. SCI ERV-24-HC11 Specifications Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Technician
Settings
ER
V
-24-HC11
With FanCycler
®
Pipersville, PA 18947 USA
Phone: 215-766 1487 - Fax: 215-766 1493
Email: [email protected] - www.scillc.com
Cat. P048013
Rev. 2.1 12.04
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - -24-HC11

Technician Settings ERV-24-HC11With FanCycler® Pipersville, PA 18947 USA Phone: 215-766 1487 - Fax: 215-766 1493 Email: [email protected] - ww

Page 2

10 6.1.2 Remote sensor wiring configurations 1. Connection of one remote sensor (RS01) 2. Connection of two remote sensors for average

Page 3 - 1. Introduction

11 7. Advanced Setup The ERV-24-HC11 thermostat with FanCycler® has enhanced features to compliment controlled mechanical ventilation systems

Page 4 - 2. Options and Accessories

12 8. Fan Cycling Configuration The purpose of fan cycling is to assure that the central air handler fan will run enough to distribute ventilatio

Page 5 - 4. Wiring Connections

13 8.1 Set the fan cycling ON time and OFF time. a. Press and hold the Select button until “LI” or ”UnLI” or ”CALC” appears on display. b. Us

Page 6 - JMP10 JMP1 JMP2

14 c. Press the Select button again – four digits will appear on display. d. Using the “+” and “-“ buttons adjust the fan cycling limited ON time

Page 7

15 8.2 Set the fan duty cycle percentage and the total period. a. Select “Calc” in 8.1.b b. Press the Select button once - “Fd” will appear on

Page 8

16 9. Ventilation Damper Cycling The purpose of cycling the ventilation damper is to limit the possibility of over-ventilating, which could cause

Page 9 - 1 2 3 4 5 6

17 9.2 Set the damper cycling CLOSE time (“dC”). a. Press the Select button until “dC” appears on display. b. Using the “+” and “-“ buttons adj

Page 10

18 11. Fan cycling at night in heating mode status (“Fn”) Depending on the duct system design and the occupants, it may be desirable to not allow

Page 11 - 7. Advanced Setup

19 12. Pump cycling for combination space and domestic hot water heating systems (“FE”) As building enclosures become more energy efficient and

Page 12 - 8. Fan Cycling Configuration

2 Please read this manual carefully before installation and use. Index Introduction 1 Options and Accessories 2 Installation Ins

Page 13

20 13. Data Storage for System Diagnostics The following data is stored by the thermostat to allow advanced system diagnostics: • Average cooli

Page 14

21 To clear the average values follow these steps: 1. Press and hold (6 seconds) the On/Off button to set the system mode to OFF 2. Using the “

Page 15

22 15. Offset Settings The Offset is used for field calibration of the measured temperature if necessary. • Press and hold (6 seconds) the On/O

Page 16

23 16. Troubleshooting for Technician Problem Solution Check the thermostat for 24 VAC, remove the front cover and test between Rc/Rh to C. Ch

Page 17

24 SCI - Systems Controls & Instruments can offer a WIDE range of products for the HVAC industry, Such as: • Flush Mount Thermostats - Prog

Page 18

3 1. Introduction Advanced Ventilation Features of the ERV-24-HC11 thermostat with FanCycler® Protected by one or more of the following pat

Page 19

4 2. Options and Accessories Remote sensor option: • RS01: for remote temperature sensing (1 required); for averaging temperature at 4 location

Page 20

5 On/Off Select ProgCoolHeatAutoFanSettingMake electrical connections as shown on enclosed electrical wiring diagram. (Next page) Verify that y

Page 21

6 JMP10 JMP1 JMP2ABA B DIP switchJMP10JMP 1 JMP 2Y2 FD The Rc/Rh terminals are bridged at the factory for a one transformer application. In the c

Page 22 - 15. Offset Settings

7 Table 5.1 – DIP switch selection DIP Switch settings FUNCTION 1 2 3 4 5 6 Internal temp. sensor1 ON x x x OFF ON Remote temp. sensor OF

Page 23

8 A BAB 5.4 Jumpers explanation Jumper 1: Complete Reset of the unit. For complete reset: • Move JMP1 to position B. • Wait 15 seconds. • Ret

Page 24 - REV 2.1

9 6. Remote temperature sensor connections – (optional) Important! The remote temperature sensor must be SCI type. Table 6.1 - N.TC. Sensor: T